Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
J Clin Med ; 12(24)2023 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-38137667

RESUMO

PURPOSE: to evaluate the clinical impact of a protocol for the image-guided percutaneous microwave ablation (MWA) of hepatocellular carcinoma (HCC) that includes cone-beam computed tomography (CBCT), fusion imaging and ablation volume prediction in patients with hepatocellular carcinoma unsuitable for standard ultrasound (US) guidance. MATERIALS AND METHODS: this study included all patients with HCC treated with MWA between January 2021 and June 2022 in a tertiary institution. Patients were divided into two groups: Group A, treated following the protocol, and Group B, treated with standard ultrasound (US) guidance. Follow-up images were reviewed to assess residual disease (RD), local tumor progression (LTP) and intrahepatic distant recurrence (IDR). Ablation response at 1 month was also evaluated according to mRECIST. Baseline variables and outcomes were compared between the groups. For 1-month RD, propensity score weighting (PSW) was performed. RESULTS: 80 consecutive patients with 101 HCCs treated with MWA were divided into two groups. Group A had 41 HCCs in 37 patients, and Group B had 60 HCCs in 43 patients. Among all baseline variables, the groups differed regarding their age (mean of 72 years in Group A and 64 years in Group B, respectively), new vs. residual tumor rates (48% Group A vs. 25% Group B, p < 0.05) and number of subcapsular tumors (56.7% Group B vs. 31.7% Group A, p < 0.05) and perivascular tumors (51.7% Group B vs. 17.1% Group A, p < 0.05). The protocol led to repositioning the antenna in 49% of cases. There was a significant difference in 1-month local response between the groups measured as the RD rate and mRECIST outcomes. LTP rates at 3 and 6 months, and IDR rates at 1, 3 and 6 months, showed no significant differences. Among all variables, logistic regression after PSW demonstrated a protective effect of the protocol against 1-month RD. CONCLUSIONS: The use of CBCT, fusion imaging and ablation volume prediction during percutaneous MWA of HCCs provided a better 1-month tumor local control. Further studies with a larger population and longer follow-up are needed.

2.
J Clin Med ; 12(20)2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37892768

RESUMO

PURPOSE: The present study aims to evaluate the effectiveness and safety of the anti-reflux microcatheter during DEB-TACE with DC Bead LUMITM (radiopaque beads) for the treatment of hepatocellular carcinoma (HCC). METHODS: We performed an observational longitudinal prospective monocentric study to analyze all patients with HCC who underwent to DEB-TACE with DC Bead LUMITM and anti-reflux microcatheter. Technical success, the presence of residual disease, and clinical success were evaluated. The performance of the anti-reflux microcatheter on the basis of the percentage of tumor covered and the non-target embolization (NTE) was also evaluated. RESULTS: Twenty patients underwent DEB-TACE with DC Bead LUMITM and an anti-reflux microcatheter. Technical success was achieved in all cases. Residual disease in the target tumor was observed in 11/20 (55%) of cases and no residual disease was found in 9/20 (45%) of cases. The clinical response at 1-month follow-up was of PD 4/20 (20%), SD 7/20 (35%), and CR 9/20 (45%). No major complications were recorded, and 10% of cases had minor complications. The distribution of beads on post-procedural CBCT, classified according to the percentage of target nodule coverage, was ≥50% in 70% (14/20) of cases and between 30-50% in 30% of cases (6/20). NTE was never registered.

3.
Technol Cancer Res Treat ; 22: 15330338231181284, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37608564

RESUMO

Tumor ablation is included in several major cancer therapy guidelines. One technical challenge of percutaneous ablation is targeting and verification of complete treatment, which is prone to operator variabilities and human imperfections and are directly related to successful outcomes, risk for residual unablated tumor and local progression. The use of "Prediction Ablation Volume Software" may help the operating Interventional Radiologist to better plan, deliver, and verify before the ablation, via virtual treatment zones fused to target tumor. Fused and superimposed images provide 3-dimensional information from different timepoints, just when that information is most useful. The aim of this study is to evaluate the technical success and efficacy of an ablation treatment flowchart provided by a cone beam computed tomography (CBCT) "Prediction Ablation Volume Software." This is a single-center retrospective study. From April 2021 to January 2022, 29 nonconsecutive evaluable patients with 32 lesions underwent liver ablation with Prediction Ablation Volume Software. Each patient was discussed in a multidisciplinary tumor board and underwent an enhanced computed tomography or magnetic resonance imaging approximately 1 month before the procedure, as well as ∼1 month after. Technical success was defined as treatment of the tumor according to the protocol, covered completely by the Prediction Ablation Volume. Technical efficacy was defined as assessment of complete ablation of the target tumor at imaging follow up (∼1 month). Technical success, technical efficacy, and procedural factors were studied. Technical success was achieved in 30 of 32 liver lesions (94%), measuring 20 mm mean maximum diameter. The antenna was repositioned in 16 of 30 (53%) evaluable target lesions. Residual tumor was detected at 1 month imaging follow up in only 4 of 30 (13%) of the treated lesion. Technical efficacy was of 87% in this retrospective description of our process. The implementation of a CBCT Prediction Ablation Volume Software and flowchart for the treatment of liver malignancies altered the procedure, and demonstrated high technical success and efficacy. Such tools are potentially useful for procedural prediction and verification of ablation.


Assuntos
Ablação por Cateter , Neoplasias Hepáticas , Humanos , Estudos Retrospectivos , Micro-Ondas/uso terapêutico , Resultado do Tratamento , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/cirurgia , Tomografia Computadorizada de Feixe Cônico/métodos , Ablação por Cateter/métodos
4.
Technol Cancer Res Treat ; 22: 15330338231185277, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37608585

RESUMO

OBJECTIVE: The aim of this study is to evaluate the feasibility, safety, and short-term effectiveness of a high-power (150 W) microwave ablation (MWA) device for tumor ablation in the lung, liver, and kidney. METHODS: Between December 2021 and June 2022, patients underwent high-power MWA for liver, lung, and kidney tumors. A retrospective observational study was conducted in accordance with the Declaration of Helsinki. The MWA system utilized a 150-W, 2.45-GHz microwave generator (Emprint™ HP Ablation System, Medtronic). The study assessed technical success, safety, and effectiveness, considering pre- and post-treatment diameter and volume, lesion location, biopsy and/or cone beam computed tomography (CBCT) usage, MWA ablation time, MWA power, and dose-area product (DAP). RESULTS: From December 2021 to June 2022, 16 patients were enrolled for high-power MWA. Treated lesions included hepatocellular carcinoma (10), liver metastasis from colon cancer (1), liver metastasis from pancreatic cancer (1), squamous cell lung carcinoma (2), renal cell carcinoma (1), and renal oncocytoma (1). Technical success rate was 100%. One grade 1 complication (6.25%) was reported according to CIRSE classification. Overall effectiveness was 92.8%. Pre- and post-treatment mean diameters for liver lesions were 19.9 mm and 37.5 mm, respectively; for kidney lesions, 34 mm and 35 mm; for lung lesions, 29.5 mm and 31.5 mm. Pre- and post-treatment mean volumes for liver lesions were 3.4 ml and 24 ml, respectively; for kidney lesions, 8.2 ml and 20.5 ml; for lung lesions, 10.2 ml and 32.7 ml. The mean ablation time was 48 minutes for liver, 42.5 minutes for lung, and 42.5 minutes for renal ablation. The mean DAP for all procedures was 40.83 Gcm2. CONCLUSION: This preliminary study demonstrates the feasibility, safety, and effectiveness of the new 150 W MWA device. Additionally, it shows reduced ablation times for large lesions.


Assuntos
Carcinoma Hepatocelular , Ablação por Cateter , Neoplasias Hepáticas , Humanos , Micro-Ondas/uso terapêutico , Ablação por Cateter/métodos , Carcinoma Hepatocelular/cirurgia , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/cirurgia , Rim/cirurgia , Pulmão/diagnóstico por imagem , Pulmão/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
5.
Diagnostics (Basel) ; 13(14)2023 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-37510092

RESUMO

Percutaneous image-guided thermal ablation is included in most society guidelines for treatment of hepatocellular carcinoma (HCC). The results of this treatment in terms of efficacy depend on the ability to precisely place the device into the target tumor. Ultrasound (US) is a commonly used imaging guidance modality for its real-time feedback. However, an accurate device deployment remains challenging in some clinical scenarios, including cases of tumors that are undetectable or not clearly visible by US. To overcome this problem, fusion imaging techniques have been developed, which combine images from different modalities. The most widely known technique combines pre-procedural contrast-enhanced computed tomography (CT) or magnetic resonance imaging (MRI) with real-time US scans. Cone beam CT (CBCT) is a technology that can provide intra-procedural cross-sectional images, which can be registered to images from other modalities, including preprocedural CT/MR scans. The aim of our study is to report the preliminary experience on percutaneous microwave ablation (MWA) of patients with HCC that were treated using the "double fusion" technique, which combines the use of US fusion imaging and CBCT fusion imaging. We describe the technical details, feasibility, safety and short-term efficacy of this technique in a small series of eight patients with 11 HCCs.

6.
Semin Ultrasound CT MR ; 44(3): 162-169, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37245882

RESUMO

Currently, minimally invasive ablative techniques for the treatment of renal tumors have become a more common and feasible treatment option. New imaging technologies have been implemented and successfully merged with each other to improve the guidance of tumor ablation. In the present review, an overview of the real-time fusion of multiple imaging modalities, robotic and electromagnetic navigation and the application of artificial intelligence software, in field of tumor renal ablation treatment, are analyzed.


Assuntos
Ablação por Cateter , Neoplasias Renais , Humanos , Inteligência Artificial , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/cirurgia , Diagnóstico por Imagem , Ablação por Cateter/métodos
7.
Technol Cancer Res Treat ; 22: 15330338231152084, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37113061

RESUMO

This review is a brief overview of the current status and the potential role of robotics in interventional radiology. Literature published in the last decades, with an emphasis on the last 5 years, was reviewed and the technical developments in robotics and navigational systems using CT-, MR- and US-image guidance were analyzed. Potential benefits and disadvantages of their current and future use were evaluated. The role of fusion imaging modalities and artificial intelligence was analyzed in both percutaneous and endovascular procedures. A few hundred articles describing results of single or several systems were included in our analysis.


Assuntos
Inteligência Artificial , Robótica , Humanos , Radiologia Intervencionista/métodos
8.
Technol Cancer Res Treat ; 22: 15330338231157193, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36916200

RESUMO

Breast cancer (BC) is the most frequently diagnosed malignancy among women. In the past two decades, new technologies and BC screening have led to the diagnosis of smaller and earlier-stage BC (ESBC). Therefore, percutaneous minimally invasive techniques (PMIT) were adopted to treat patients unfit for surgery, women who refuse it, or elderly patients with comorbidities that could make surgery a difficult and life-threatening treatment. The target of PMIT is small-size ESBC with the scope of obtaining similar efficacy as surgery. Minimally invasive treatments are convenient alternatives with promising effectiveness, lower morbidity, less cost, less scarring and pain, and more satisfying cosmetic results. Ablative techniques used in BC are cryoablation, radiofrequency ablation, microwave ablation, high-intensity focused ultrasound (US), and laser ablation. The aim of our study is to discuss the current status of percutaneous management of BC, evaluate the clinical outcomes of PMIT in BC, and analyze future perspectives regarding ablation therapy in BC.


Assuntos
Técnicas de Ablação , Neoplasias da Mama , Ablação por Cateter , Criocirurgia , Ablação por Ultrassom Focalizado de Alta Intensidade , Terapia a Laser , Humanos , Feminino , Idoso , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/cirurgia , Criocirurgia/métodos , Técnicas de Ablação/métodos , Terapia a Laser/métodos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Ablação por Cateter/métodos
9.
Jpn J Radiol ; 40(4): 341-366, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34951000

RESUMO

Dynamic contrast-enhanced (DCE) imaging is a non-invasive technique used for the evaluation of tissue vascularity features through imaging series acquisition after contrast medium administration. Over the years, the study technique and protocols have evolved, seeing a growing application of this method across different imaging modalities for the study of almost all body districts. The main and most consolidated current applications concern MRI imaging for the study of tumors, but an increasing number of studies are evaluating the use of this technique also for inflammatory pathologies and functional studies. Furthermore, the recent advent of artificial intelligence techniques is opening up a vast scenario for the analysis of quantitative information deriving from DCE. The purpose of this article is to provide a comprehensive update on the techniques, protocols, and clinical applications - both established and emerging - of DCE in whole-body imaging.


Assuntos
Neoplasias , Imagem Corporal Total , Inteligência Artificial , Meios de Contraste , Humanos , Imageamento por Ressonância Magnética/métodos
10.
Surg Technol Int ; 39: 317-320, 2021 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-34699598

RESUMO

Caval filters are placed in the inferior vena cava (IVC) to prevent pulmonary thromboembolism in patients with deep vein thrombosis. If there is no indication for thrombo-embolic risk prevention, the filter can be removed to reduce potential filter-related complications. Advanced endovascular techniques are frequently used to retrieve IVC filters. We describe an alternative filter-removal technique for use when standard techniques are not practicable. In our method, the filter hook is embedded within the IVC wall. To retrieve it, a long introducer is inserted; a guidewire and the "loop snare" retrieval system are then advanced through it with a coaxial system and positioned below the filter at the level of the common iliac vein confluence. The guidewire is then passed through the loop, creating a "sling" around the filter which allows the application of traction from the bottom upwards, releasing the hook from the wall. The loop is then held under tension with the filter aligned in the IVC lumen, and the introducer is advanced distally to completely cover the filter, allowing complete retrieval of the filter without damaging the vessel walls. This modified Sling technique is a safe and feasible method for complicated IVC filter retrieval.


Assuntos
Procedimentos Endovasculares , Filtros de Veia Cava , Remoção de Dispositivo , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Veia Cava Inferior/cirurgia
11.
Med Oncol ; 38(10): 126, 2021 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-34495438

RESUMO

The aim of the study is to evaluate the performance of a simplified ABLATE score (sABLATE) in predicting complications and outcome with respect to RENAL, mRENAL, and ABLATE scores. This study included 136 renal lesions in 113 patients (M:F ratio = 2.5; mean age 70.8 years). 98 tumors underwent cryoablation at San Raffaele hospital between 01/2015 and 03/2020, while 37 underwent microwave ablation at San Paolo or Policlinico hospitals between 07/2016 and 03/2020. RENAL, mRENAL, ABLATE, and sABLATE scores were calculated using pre-procedural imaging. Data regarding complications and follow-up were registered. Mann-Whitney U test, ROC analyses, and logistic regression analyses were used for complications. Cox-regression analyses were performed for outcome. Mean tumor diameter was 23.2 mm. Mean and median RENAL, mRENAL, ABLATE, and sABLATE scores were 6.8 and 7, 6.9 and 7, 5.3, and 5, and 3.5 and 3, respectively. During a mean follow-up of 21.9 months (range 1-73), we registered 7 complications, 3 cases of residual disease, and 10 local tumor progressions. Mann-Whitney U test p values for complications for RENAL, mRENAL, ABLATE, and sABLATE were 0.51, 0.49, 0.66, and 0.056, respectively. ROC analyses for complications showed an AUC for RENAL, mRENAL, ABLATE, and sABLATE of 0.57, 0.57, 0.55, and 0.71, respectively. Regarding outcome, HR and p values of Cox-regression analyses were 1.30 and 0.36 for RENAL, 1.33 and 0.35 for mRENAL, 2.16 and 0.01 for ABLATE, 2.29 and 0.004 for sABLATE. sABLATE was the only score close to significance for complications, representing a progress even if not definitive. Regarding outcome, ABLATE confirmed its value, and sABLATE maintained validity despite being a simplification.


Assuntos
Criocirurgia , Neoplasias Renais/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Neoplasias Renais/diagnóstico , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia , Neoplasia Residual , Complicações Pós-Operatórias , Estudos Retrospectivos , Resultado do Tratamento
12.
Radiol Case Rep ; 16(10): 3113-3116, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34457098

RESUMO

Vertebral fractures are the most frequent fractures associated with osteoporosis. Thus far, there are no reported cases in literature analyzing intervertebral bleeding as a result of an osteoporotic vertebral fracture. The authors report a case of an 85-year-old woman in hemorrhagic shock for an unusual vertebral fracture causing a massive bleeding, which was contained by the vertebral ligament system inside the body of L4, treated with an endovascular approach. Since there are no guidelines for a treatment for the case mentioned above or similar, our aim is to describe a possible approach to a potentially life-threatening rare event.

13.
Acta Biomed ; 92(S1): e2021159, 2021 04 30.
Artigo em Inglês | MEDLINE | ID: mdl-33944842

RESUMO

Chemodectomas are rare neuroendocrine tumors that typically arise at the carotid bifurcation and progressively englobe the internal and external carotid artery. Surgical asportation of the capsulated mass is the elective treatment. Pre-procedural embolization of this high vascular tumors is highly recommended because it has shown to improve surgical outcome by reducing both, mean blood loss and total operation time. Many different embolization techniques have been described in literature. In the here presented case we opted for an endovascular approach using resorbable purified porcine skin gelatin cross-linked with glutaraldehyde microspheres (Optisphere - MEDTRONIC) as an embolic agent. These turned out to be very safe and effective in improving surgical outcome by reducing operative blood loss and thus reducing treatment-related morbidity.


Assuntos
Tumor do Corpo Carotídeo , Embolização Terapêutica , Animais , Tumor do Corpo Carotídeo/terapia , Gelatina , Glutaral , Suínos , Resultado do Tratamento
14.
Radiol Med ; 126(7): 998-1006, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33861421

RESUMO

Artificial intelligence (AI) is a branch of Informatics that uses algorithms to tirelessly process data, understand its meaning and provide the desired outcome, continuously redefining its logic. AI was mainly introduced via artificial neural networks, developed in the early 1950s, and with its evolution into "computational learning models." Machine Learning analyzes and extracts features in larger data after exposure to examples; Deep Learning uses neural networks in order to extract meaningful patterns from imaging data, even deciphering that which would otherwise be beyond human perception. Thus, AI has the potential to revolutionize the healthcare systems and clinical practice of doctors all over the world. This is especially true for radiologists, who are integral to diagnostic medicine, helping to customize treatments and triage resources with maximum effectiveness. Related in spirit to Artificial intelligence are Augmented Reality, mixed reality, or Virtual Reality, which are able to enhance accuracy of minimally invasive treatments in image guided therapies by Interventional Radiologists. The potential applications of AI in IR go beyond computer vision and diagnosis, to include screening and modeling of patient selection, predictive tools for treatment planning and navigation, and training tools. Although no new technology is widely embraced, AI may provide opportunities to enhance radiology service and improve patient care, if studied, validated, and applied appropriately.


Assuntos
Algoritmos , Inteligência Artificial , Aprendizado de Máquina , Radiologia Intervencionista/métodos , Humanos
15.
Semin Ultrasound CT MR ; 42(1): 85-94, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33541592

RESUMO

The strict correlation between abnormal invasive placentation and postpartum hemorrhage suggests that a widespread antenatal diagnosis of placental anomalies would improve the management of these challenging patients; acting preventive solutions at the moment of delivery reduces blood loss and avoid hysterectomies. The role of endovascular procedures in this field has been encouraged by multiple studies reporting prophylactic uterine arteries embolization and iliac/aortic balloon catheters positioning. This paper aims to review the main imaging diagnostic findings of placental implant anomalies and summarize the principal preventive endovascular strategies proposed in literature.


Assuntos
Procedimentos Endovasculares/métodos , Imageamento por Ressonância Magnética/métodos , Hemorragia Pós-Parto/diagnóstico por imagem , Hemorragia Pós-Parto/prevenção & controle , Ultrassonografia/métodos , Feminino , Humanos , Hemorragia Pós-Parto/cirurgia , Gravidez
16.
Minim Invasive Ther Allied Technol ; 30(1): 33-39, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31553249

RESUMO

PURPOSE: To assess a correlation between the shrinkage of the fibroid and the course of the symptoms. MATERIAL AND METHODS: Fourteen patients with symptomatic uterine leiomyomas (mean fibroid volume: 111.45 cm3) underwent percutaneous microwave ablation. Contrast-enhanced MRI follow-up was performed before and after treatment to evaluate the volume shrinkage. Two scores obtained from the Uterine Fibroids Symptom and Quality of Life questionnaire were used to perform a clinical follow-up to evaluate the symptoms and the quality of life at baseline, and at 3, 6 and 12 months after treatment. RESULTS: All patients were treated, no complications occurred. During a mean MR follow-up of 8.1 months we observed shrinkage of the fibroids in all patients (mean 70.3 cm3). During 12 months clinical follow-up, we observed a significant improvement of symptoms and an excellent improvement of quality of life (p < .001). CONCLUSION: Uterine fibroids percutaneous microwave ablation is a safe tool to obtain a significant improvement in quality of life for all the patients of our cohort.


Assuntos
Leiomioma , Neoplasias Uterinas , Feminino , Humanos , Leiomioma/cirurgia , Micro-Ondas , Qualidade de Vida , Resultado do Tratamento , Neoplasias Uterinas/cirurgia
17.
Reprod Sci ; 28(1): 27-30, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32729020

RESUMO

Heterotopic cervical pregnancy is a rare and potentially dangerous condition where the challenge is the removal of the ectopic pregnancy while preserving the intrauterine one. We present the case of an otherwise healthy 36-year-old woman with heterotopic cervical pregnancy after an IVF cycle for tubal infertility. At 6.5 weeks after a consultation with gynecologists and interventional radiologists, the patient agreed to undergo microwave ablation of the cervical pregnancy. Monthly ultrasound examination showed the persistence of non homogeneous and vascularized tissue in the cervix. Intrauterine pregnancy continued without complications until 37 weeks when a cesarean section was performed for sudden and profuse bleeding, in the presence of uterine contractions. A healthy baby girl was delivered, and the postoperative course was otherwise uncomplicated. Heterotopic cervical pregnancies are rare, and no consolidated and risk-free treatments are available at the moment. Here, we present a case of heterotopic cervical pregnancy treated successfully and without complications with microwave ablation.


Assuntos
Técnicas de Ablação , Transferência Embrionária/efeitos adversos , Fertilização In Vitro/efeitos adversos , Micro-Ondas/uso terapêutico , Gravidez Heterotópica/cirurgia , Adulto , Feminino , Humanos , Gravidez , Gravidez Heterotópica/diagnóstico , Gravidez Heterotópica/etiologia , Resultado do Tratamento
18.
Radiol Med ; 126(1): 5-13, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32458272

RESUMO

PURPOSE: To determine the effectiveness of liver reporting and data system (LI-RADS) to diagnose hepatocellular carcinoma (HCC) and to retrospectively evaluate its impact on the adopted therapeutic strategy. MATERIALS AND METHODS: Preoperative imaging of 40 of 350 patients (median age 66, 31 M/9 F) submitted to liver resection for suspected HCC, between January 2008 and August 2019, has been retrospectively analyzed by two radiologists with different expertise, according to CT/MRI LI-RADS® v2018, both blinded to clinical and pathological results and untrained to using aforementioned scoring system. RESULTS: The perfect agreement between the readers was about 62.5% (25/40) (Cohen k: 0.41), better for LR-5 category (16/25) and higher in magnetic resonance imaging (MRI) investigations (68%; 13/19), which has been demonstrated the modality of choice for diagnosis of high probable and certain HCC, with arterial phase hyperenhancement as the most sensitive and accurate major feature. Compared to final histology, LR4 and LR5 scores assigned by senior radiologist reached sensitivity, specificity, positive and negative predictive values (PPV, PNV) and diagnostic accuracy of 90,9%, 29,0%, 93,8%, 62,5% and 87,5%, respectively, slightly higher than junior's ones. Misdiagnosis of HCC was done by both radiologists in the same two patients: 1 primary hepatic lymphoma (PHL) and 1 regenerative liver nodule (RLN). If LI-RADS would have been applied at the time of pre-surgical imaging, treatment planning would be modified in 10% of patients (4/40); the patient scheduled as LR-3 and finally resulted a focal nodular hyperplasia would have avoided liver resection. CONCLUSIONS: Application of LI-RADS, especially on MRI, may provide a more accurate evaluation of suspected HCC. PHL and RLN are the Achille's heels according to our experience.


Assuntos
Algoritmos , Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Idoso , Carcinoma Hepatocelular/cirurgia , Diagnóstico Diferencial , Feminino , Humanos , Aumento da Imagem , Interpretação de Imagem Assistida por Computador , Neoplasias Hepáticas/cirurgia , Imageamento por Ressonância Magnética , Masculino , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
19.
J Vasc Access ; 22(4): 654-657, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32815482

RESUMO

This report aims to illustrate how to perform a venous access to a COVID-19 patient at the bedside. The decision on the type of venous access, the selection of the material necessary to perform the procedure, and the preparation of the operators are described. The described approach can reduce costs, speed up execution times, and make the operator's work safer. Furthermore, these precautions may help control the spread of COVID-19 within the healthcare facility.


Assuntos
COVID-19/diagnóstico , Cateterismo Venoso Central/métodos , Cateteres Venosos Centrais , Pandemias , Testes Imediatos , COVID-19/epidemiologia , Humanos , Radiografia Intervencionista/métodos , SARS-CoV-2
20.
Ann Gastroenterol ; 33(6): 675-679, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33162745

RESUMO

BACKGROUND: The aim of this study was to evaluate the diagnosis and management of postoperative bile leaks, reporting typical diagnostic findings and available percutaneous techniques in association with other diagnostic and management methods. METHODS: Thirty-six patients (28 male) were treated for postoperative bile leaks. A biliary leak was clinically suspected in case of persistent leakage of bilious material from a surgical drain, or in the presence of non-specific symptoms such as abdominal pain, fever and anorexia, with or without laboratory alteration of liver enzymes. Radiological confirmation was mainly based on noninvasive methods such as ultrasound, computed tomography, and magnetic resonance cholangiopancreatography. We assessed each treatment by evaluating multiple factors, including technical success (TS) and clinical effectiveness (CE), defined as primary or secondary. We also evaluated overall CE (OCE), defined as leak control with either single or multiple procedures. RESULTS: TS and OCE were achieved in all patients (36/36; 100%) with a grade A or B biliary leak. No grade C was observed. There were no major complications. Minor complications were observed in 7/36 (19.4%) patients. No procedure-related deaths occurred. CONCLUSIONS: In our study, considering all percutaneous techniques, leak healing was achieved in all the patients with a grade A or B biliary leak. These procedures provide a less invasive approach and are increasingly recognized as having a significant role in the management of complications and should be considered as an integral component in the postoperative management of these patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...